Design of Unreinforced Masonry Wall
General:
Unreinforced masonry walls are often used as load
bearing or non-loading interior wall in one story building. Although it is
called “unreinforced”, the masonry wall still needs to be reinforced
with joint reinforcements. In
addition, ordinary and detailed plan masonry walls are allowed as shear
walls in seismic design category A & B.
But it still needs to meet code required minimum reinforcement
requirements. By definition of
ACI 530 Section 1.6, the tensile strength of masonry is considered, but the
strength of reinforcing steel is neglected.
Load on masonry walls:
- Vertical
dead load, live load, snow load, etc.
- Lateral
load from wind, seismic, earth pressure etc.
Stresses in concrete masonry wall:
- Compressive
stress from vertical load
- Compressive
stress from flexural moment due to lateral load.
- Tensile
stress from flexural moment due to lateral load, eccentric moment, etc.
Design requirements:
When the wall, pilaster, and column is subjected to
axial compression and flexure.
- The
maximum compression stress shall satisfy the following equation
fa/Fa +
fb/Fb £
1
(ACI 530 Eq. 2-10)
Where, fa is compressive stress from axial
load, fb is compressive stress from flexure; Fa and Fb,
Fv are allowable
compressive stress and tensile stress calculation from equation below:
For member with h/r £
99:
Fa = (1/4) fm’
{1-[h/(140r)]2}
(ACI 530 2-12)
For member with h/r > 99:
Fa = (1/4) fm’
(70r/h)2
(ACI 530 2-13)
Where h is effective height of wall, column or
pilaster, r is radius of gyration, fm’ is compressive strength of masonry
Allowable compressive stress from flexure:
Fb = (1/3) fm’
(ACI 530 2-14)
- The
maximum axial force P shall satisfy the following equation
P£
(1/4) Pe
(ACI 530 Eq. 2-11)
Where Pe is calculated as
Pe = [p2EmI/h2][1-0.577*e/r)2
(ACI 530 2-15)
Where Em is elastic modulus of masonry, I is
moment of inertia, h is the height of wall, column or plaster, e is
eccentricity of axial load, r is radius of gyration.
- The
tensile stress due to flexure shall not exceed the value listed in ACI
530 Table 2.2.3.2. as shown below:
Allowable flexural tension stress for hollow core
concrete masonry unit, psi.
|
Masonry
|
Mortar
|
|
Portland cement/lime or mortar cement
|
Masonry cement or air entrained Portland
cement/lime
|
|
Normal to bed joints
|
M or S
|
N
|
M or S
|
N
|
|
Ungrouted hollow units
|
25
|
19
|
15
|
9
|
|
Grout hollow units
|
68
|
58
|
41
|
29
|
|
Parallel to bed joints in running bond
|
M or S
|
N
|
M or S
|
N
|
|
Ungrouted or partially grout hollow units
|
50
|
38
|
30
|
19
|
|
Fully grouted hollow units
|
80
|
60
|
48
|
30
|
Example 1: Design of an interior unreinforced load bearing masonry wall
Design
data:
Roof
dead load: 20 psf
Roof
live load: 20 psf
Tributary
width: 30 ft
Height
of wall: 12 ft
Normal
width of wall: 8 in
Assume
minimum eccentricity: 0.8 in
Seismic
load from ASCE 7: 4 psf
Requirement:
Check if an 8 in unreinforced masonry wall is adequate
Solution:
Axial
load per foot width of wall from roof, P = (20 psf+20 psf)*30 psf = 1200
lb/ft
Eccentricity:
e = 0.8 in
Eccentric
moment: Mc = 1200*0.8/12 = 80 lb/ft
Seismic
moment: Ms = 5 psf * (12ft)2/8 = 90 lb-ft/ft
Moment
per foot width of wall, M = (80 + 90) lb-ft/ft = 170 lb-ft/ft
Width
of wall: 7.625 in
Cross
section area: A = 42.8 in2.
Moment
of inertia: I = 330.9 in4.
Section
modulus: S = 86.8 in3.
Radius
of gyration: r = 2.78 in
Check
flexural tensile stress: fb = M/S = 170*12/86.8 = 23.5 psf
Less
than allowable tensile stress 25 psi for ungrouted hollow unit O.K.
Check
compressive stress:
Weight
of wall at mid-height: W = 55 psf * 6 ft = 330 lb/ft
Axial
compressive stress: fa = (P+W)/A = 35.8 psi/ft
Slenderness
ratio: h/r = 12*12/2.78 = 51.7 <
99
Use
1900 psi concrete masonry units with type S mortar,
Compressive
strength of concrete masonry, fm’ = 1500 psi
Fa
= (1/4) fm’ {1-[h/(140r)]2} = 323.7 psi
Allowable
flexural strength:
Fb
= (1/3) fm’
= 500 psi
Combined
stress equation:
fa/Fa
+ fb/Fb = 0.158 < 1
O.K.
Check
axial force:
Elastic
modulus, Em = 900 fm’ = 1.35x106 psi
Pe
= [p2EmI/h2][1-0.577*e/r)2=
1.23x105 lb
(1/4)
Pe = 3.09 x 104 lb > 1200+330 = 1530 lb
O.K.
|