Custom Search

 

Beam to beam double angle bolted  bearing type connection

LRFD Design Example:

Situation: A structural steel beam to beam double angle bearing type connection is shown below.

Design code: AISC 13th edition. LRFD

Design data:

Connection beam: W12x40, ASTM A992

Supporting beam: W18x35, ASTM A992

Angle: L3x3x1/4, ASTM A36

Bolt: 2/4" diameter, ASTM A325-N (thread not excluded)

Live load reaction: 25 kips

Dead load reaction: 25 kips

Requirement: Check if the connection design is adequate.

Calculated factored reaction

Factored reaction: Ru = 1.2 (25) + 1.6 (25) = 70 kips

Check number of bolts in W12x40:

Resistance factor: f = 0.75

Nominal shear strength of A325-N bolt, Fnv = 48 ksi

Gross section of 3/4" diameter bolts: 0.442 in2.

Bolt strength in single shear: fRn = (0.75)(48)(0.442) = 15.9 kip

This value is shown in AISC manual, 13th ed. Table 7-1.

Number of bolts in W12x40 in double shear: N = Ru / 2 fRn = 2.2  < 3 O.K.

Check number of bolts in W18x35

Distance from center of bolts in W12x40 to face of support = 1.25+0.5 = 1.75 in

Moment due to eccentricity: Mu = (70)(1.75) = 122.5 in-kip

Assume neutral axis of bolt group is at middle, moment of inertia of bolt group

I = 4 (3 in)2 = 36 in2.

Tension in bolt: Tu = (122.5)(3)/36 = 10.2 kip

Shear stress in bolt, fv = 70/[(6)(0.442)] = 26.4 ksi

Nominal tensile stress of A325 bolt is 90 ksi. Available tensile stress in bolt:

F'nt = (1.3)(90)-[(90)/(0.75)(48)](26.4) = 51 ksi

Available tensile strength of bolt = (0.75)(51)(0.442) = 16.9 kip > 10.2 kip O.K.

Check bolt bearing in beam web:

Web thickness of W12x40: 5/16 inches

Resistance factor: f = 0.75

Bolt hole for 3/4" bolt = 7/8"

Clear distance between bolts: 3" - 7/8" = 2.125"

Clear distance between bolt and edge of angle = 1.5"-7/16" = 1.063"

Minimum tensile strength of A992 material: Fu = 65 ksi

Nominal bearing strength: Rn = 1.2 [2(2.125)+1.063)](5/16)(65) = 129.5 kips

Maximum bearing strength: 2.4d tw Fu = 2.4 (3/4)(5/16)(65) (3) = 109.7 kips

Bearing strength: (0.75)(109.7) = 82.3 kip > 70 kips O.K.

Check shear strength of beam web

Check shear yield of beam web

Length of copped beam: 12-1.5 = 10.5"

Gross shear area: (10.5)(5/16) = 3.28 in2.

Resistance factor: f = 1.0

Shear strength of web, fRn = f (0.6 Fy Ag) = (1)(0.6)(50)(3.28) = 98.4 kip > 70 kips O.K.

Check shear rupture of beam web:

Net length of copped beam: 12-1.5-(3)(7/8) = 7.875"

Net area Anv = (7.875)(5/16) = 2.46 in2.

Resistance factor: f = 0.75

Shear strength of web: fRn = f (0.6 Fu Anv) = (0.75)(0.6)(65)(2.46) = 72 kip > 70 kips O.K.

Check block shear of beam web

Resistance factor: f = 0.75

Net shear area of block shear: Anv = (7.5-7/16)(5/16) = 2.21 in2

Assume the gap between end of W12x40 and web of W18x35 is 1/2".

The edge distance of bolt to end of beam is 1.25".

Net tension area of block shear: Ant = (1.25-7/16)(5/16) = 0.254 in2.

Gross section of shear area: Agv = (10.5)(5/16) = 3.28 in2.

Factored Ubs = 1 for single column of bolt

Nominal block shear strength: f Rn = 0.75(0.6FuAnv+UbsFuAnt) = 77 kip > 70 kips O.K.

Maximum block shear strength: f (0.6FyAgv+UbsFuAnt) = 84.9 kip

Check L3x3x1/4" angle

Factored load on each angle = 70/2 = 35 kips

Check bolt bearing on angle

Resistance factor: f = 0.75

Clear distance between bolts: 3 -7/8 = 2.125"

Clear distance between bolt and edge of angle: 1.5-7/16 = 1.063"

Tensile strength of A36 steel, Fu = 58 ksi

Bearing strength: fRn = (0.75)(1.5)[(2(2.125)+1.063)](1/4) (58) = 69.3 kips 

Maximum bearing strength:  f(2.4d tw Fu ) = (0.75)[2.4 (3/4)(1/4)(58)](3) = 58.7 kips > 35 ksi O.K.

Check shear strength of angle

Check shear yield of angle

Length of angle: 9"

Gross shear area: (9)(1/4) = 2.25 in2.

Resistance factor: f = 1.0

Shear strength of web, fRn = f (0.6 Fy Ag) = (1)(0.6)(36)(2.25) = 48.6 kip > 35 kips O.K.

Check shear rupture of angle:

Net length of angle: 9-(3)(7/8) = 6.375"

Net area Anv = (6.375)(1/4) = 1.594 in2.

Resistance factor: f = 0.75

Shear strength of web: fRn = f (0.6 Fu Anv) = (0.75)(0.6)(58)(1.594) = 41.6 kip > 35 kips O.K.

Check block shear of angle

Resistance factor: f = 0.75

Net shear area of block shear: Anv = (7.5-7/16)(1/4) = 1.77 in2

The edge distance of bolt is 1.25".

Net tension area of block shear: Ant = (1.25-7/16)(1/4) = 0.203 in2.

Gross section of shear area: Agv = (9)(1/4) = 2.25 in2.

Factored Ubs = 1 for single column of bolt

Nominal block shear strength: f Rn = 0.75(0.6FuAnv+UbsFuAnt) = 54.9 kip 

Maximum block shear strength: f (0.6FyAgv+UbsFuAnt) = 45.3 kip > 35 kips O.K.

 

 
Disclaimer:  The content of this website was obtained and edited from various resources.  The editor made reasonable effort of editing.  Nevertheless, the editor does not warrant, and assume no liability for accuracy and completeness of its content.  The viewer shall use his/her professional knowledge and judgment in use of the web content.        Webmaster: www.ce-ref.com