Custom Search
|
|
|
Beam to beam double bolted bearing type connectionASD Design Example:Situation: A structural steel beam to beam double angle bearing type connection is shown below.
Design code: AISC 13th edition. ASD Design data: Connection beam: W12x40, ASTM A992 Supporting beam: W18x35, ASTM A992 Angle: L3x3x1/4, ASTM A36 Bolt: 2/4" diameter, ASTM A325-N (thread not excluded) Live load reaction: 25 kips Dead load reaction: 25 kips Requirement: Check if the connection design is adequate.
Calculated factored reactionService load reaction: R = 25 + 25 = 50 kips Check number of bolts in W12x40:Safety factor: W = 2 Nominal shear strength of A325-N bolt, Fn = 48 ksi Gross section of 3/4" diameter bolts: 0.442 in2. Bolt strength in single shear: Rn / W= (48)(0.442) / 2 = 10.6 kip This value is shown in AISC manual, 13th ed. Table 7-1. Number of bolts in W12x40 in double shear: N = R / 2 (Rn / W) = 2.4 < 3 O.K. Check number of bolts in W18x35Distance from center of bolts in W12x40 to face of support = 1.25+0.5 = 1.75 in Moment due to eccentricity: M = (50)(1.75) = 87.5 in-kip Assume neutral axis of bolt group is at middle, moment of inertia of bolt group I = 4 (3 in)2 = 36 in2. Tension in bolt: T = (87.5)(3)/36 = 7.3 kip Shear stress in bolt, fv = 50/[(6)(0.442)] = 18.9 ksi Nominal tensile stress of A325 bolt is 90 ksi. Available tensile stress in bolt: F'nt = (1.3)(90)-[(2)(90)/(48)](18.9) = 46.3 ksi Allowable tensile strength of bolt = (46.3)(0.442)/2 = 10.2 kip > 7.3 kip O.K. Check bolt bearing in beam web:Web thickness of W12x40: 5/16 inches Safety factor: W = 2 Bolt hole for 3/4" bolt = 7/8" Clear distance between bolts: 3" - 7/8" = 2.125" Clear distance between bolt and edge of angle = 1.5"-7/16" = 1.063" Minimum tensile strength of A992 material: Fu = 65 ksi Nominal bearing strength: Rn = 1.2 [2(2.125)+1.063)](5/16)(65) = 129.5 kips Maximum bearing strength: 2.4d tw Fu = 2.4 (3/4)(5/16)(65) (3) = 109.7 kips Bearing strength: 109.7/2 = 54.8 kip > 50 kips O.K. Check shear strength of beam webCheck shear yield of beam web Length of copped beam: 12-1.5 = 10.5" Gross shear area: (10.5)(5/16) = 3.28 in2. Safety factor: W = 1.5 Shear strength of web, Rn / W = (0.6 Fy Ag)/W = (1)(0.6)(50)(3.28)/1.5 = 65.6 kip > 50 kips O.K. Check shear rupture of beam web: Net length of copped beam: 12-1.5-(3)(7/8) = 7.875" Net area Anv = (7.875)(5/16) = 2.46 in2. Safety factor: W = 2 Shear strength of web: Rn /W= (0.6 FuAnv)/W = (0.6)(65)(2.46)/2 = 64 kip > 50 kips O.K. Check block shear of beam webSafety factor: W = 2 Net shear area of block shear: Anv = (7.5-7/16)(5/16) = 2.21 in2. Assume the gap between end of W12x40 and web of W18x35 is 1/2". The edge distance of bolt to end of beam is 1.25". Net tension area of block shear: Ant = (1.25-7/16)(5/16) = 0.254 in2. Gross section of shear area: Agv = (10.5)(5/16) = 3.28 in2. Factored Ubs = 1 for single column of bolt Nominal block shear strength: Rn /W= (0.6FuAnv+UbsFuAnt)/W = 51.3 kip > 50 kips O.K. Maximum block shear strength: (0.6FyAgv+UbsFuAnt)/W = 57.5 kip Check L3x3x1/4" angleService load on each angle = 50/2 = 35 kips Check bolt bearing on angleSafety factor: W = 2 Clear distance between bolts: 3 -7/8 = 2.125" Clear distance between bolt and edge of angle: 1.5-7/16 = 1.063" Tensile strength of A36 steel, Fu = 58 ksi Bearing strength: Rn /W = (1.5)[(2(2.125)+1.063)](1/4) (58)/2 = 57.8 kips Maximum bearing strength: (2.4d tw Fu )/W = [2.4 (3/4)(1/4)(58)](3)/2 = 39.5 kips > 25 ksi O.K. Check shear strength of angleCheck shear yield of angle Length of angle: 9" Gross shear area: (9)(1/4) = 2.25 in2. Safety factor: W = 1.5 Shear strength of web, Rn /W= (0.6 Fy Ag)/W = (0.6)(36)(2.25)/1.5 = 32.4 kip > 25 kips O.K. Check shear rupture of angle: Net length of angle: 9-(3)(7/8) = 6.375" Net area Anv = (6.375)(1/4) = 1.594 in2. Safety factor: W = 2 Shear strength of web: Rn /W = (0.6 Fu Anv)/W = (0.6)(58)(1.594)/2 = 27.7 kip > 25 kips O.K. Check block shear of angleSafety factor: W = 2 Net shear area of block shear: Anv = (7.5-7/16)(1/4) = 1.77 in2. The edge distance of bolt is 1.25". Net tension area of block shear: Ant = (1.25-7/16)(1/4) = 0.254 in2. Gross section of shear area: Agv = (9)(1/4) = 2.25 in2. Factored Ubs = 1 for single column of bolt Nominal block shear strength: Rn /W = 0.75(0.6FuAnv+UbsFuAnt)/W = 36.6 kip Maximum block shear strength: (0.6FyAgv+UbsFuAnt)/W = 30.2 kip > 25 kips O.K.
|
| Disclaimer: The content of this website was obtained and edited from various resources. The editor made reasonable effort of editing. Nevertheless, the editor does not warrant, and assume no liability for accuracy and completeness of its content. The viewer shall use his/her professional knowledge and judgment in use of the web content. Webmaster: www.ce-ref.com |