CE-Ref.COM

Google
 

 

Design of W, I, S, HSS steel columns for axial compression (13 edition)

Design code: AISC 13ed.

Design requirements

LRFD (Load and Resistance Factor) design:

LRFD design:

  1. Pu £ fPn.

Where Pu is factored axial compressive force calculated based on strength design provision of building code.  Pn is  axial compressive strength calculated based on AISC 13th edition, f = 0.9 is resistance factor.

ASD (Allowable Stress ) design:

  1. Pa £ Pn/W.

Where Pa is axial compressive force calculated based on allowable stress design provision of building code, Pn is  normal compressive strength calculated based on AISC 13th edition, W = 1.67 is safety factor.

Design procedure:

LRFD

  1. Calculate factored load based on strength design provision of building code
  2. Calculate factored axial compressive force, Pu.
  3. Select a trial column size and calculate normal axial compressive strength, Pn from Chapter E of AISC 13th edition.
  4. Multiply Pn by f = 0.9. and compare fPn with Pu.

ASD design:

  1. Calculate apply load based on allowable stress design provision of building code
  2. Calculate apply axial compressive force, P.
  3. Select a trial column size and ccalculate normal axial compressive strength, Pn from Chapter E of AISC 13th edition
  4. Divide Pn by W = 1.67 and compare Pn/W with P.

Determine factored axial force, Pu for strength design & P for allowable stress design

Load combination factor: 

shall be determined according to applicable building code.  Use ASCE 7 when building code is not available.

Determine axial compressive strength,  Pn

  1. Determine slenderness ratio in both axes.

KxLx/rx and KyLy/ry

where

Lx ,Ly are laterally unsupported lengths in X and Y direction,

rx ,rx are radius of gyrations in X and Y direction

Ky ,Ky are slenderness factors in X and Y direction and can be determined as

  1. Calculate, l = 4.71ÖE/Fy or Fe = p E/(KL/r)2 where E is elastic modulus, Fy is yield strength of steel.
  1. If KL/r £  l , or Fe ³ 0.44 Fy then Fcr = (0.685Fy/Fe ) Fy  
  2. If KL/r >  l , or Fe < 0.44 Fy then Fcr = 0.877 Fe  
  3. LRFD - The axial compressive strength, fPn = 0.9AgFcr, where Ag is gross section area of member.
  4. ASD - The allowable axial compression, Pa = AgFcr/1.67.

Example 1:

Situation: A structural column is supporting roof

Design Code: AISC ASD 13th edition

Roof live load: WL = 20 psf

Roof dead load: WD = 20 psf

Unsupported Length of column: Lux = 15 ft, Luy = 15 ft

Top and bottom of column is pinned

Tributary area 30 ft x 30 ft

Material: ASTM A36, yield strength, Fy = 50 ksi

Requirements:  Select a W6 beam

Solution:

Try W6x15, A = 4.43 in2, rx = 2.56 in, ry = 1.46 in

Slenderness factor, Kx = 1, Ky = 1

Slenderness ratio, KxLux/rx = 70.3, KyLuy/ry = 123.3

Elastic modulus, E = 29000 ksi

parameter, l = (4.71)Ö(29000/50) = 113.4   < 123.3

Fe = (3.14)2(29000)/(123.3)2 = 18.83 ksi

Fcr = (0.877)(18.83)= 16.5 ksi  

LRFD solution

Compressive strength of column, fPn = 0.9(4.43)(16.5) = 65.8 kips   O.K.

Factored column load: Pu = {[(1.2)(20)+(1.6)(20)](30)(30)+1.2(15)(15)}/1000 = 50.67 kip

ASD solution

Allowable column load: Pa = (16.5)(4.43)/1.67 = 43.8 kips    

Apply column load: P = {[(20)+(20)](30)(30)+(15)(15)}/1000 = 36.2 kip  O.K.

Example 2:

Situation: In example 1 assume that the column is supported laterally at mid-height of column in minor axis,

Requirement: Select an economical column

Solution:

Try W6x9, A = 2.68 in2, rx = 2.47 in, ry = 0.905 in.

Lateral unsupported length, Lux = 15 ft, Luy = 7.5 ft

Slenderness ratio, KxLux/rx = 72.8, KyLuy/ry = 99.4

Slenderness parameter, l = (4.71)Ö(29000/50) = 113.4   >  99.4

Fe = (3.14)2(29000)/(99.4)2 = 28.94 ksi

Fcr = [(0.658)(50/28.94)](50) = 24.26 ksi  

LRFD solution

Compressive strength of column, fPn = 0.85(2.68)(26) = 59.2 kips   

Factored column load: Pu = {[(1.2)(20)+(1.6)(20)](30)(30)+1.2(9)(15)}/1000 = 50.56 kip  O.K.

ASD solution

Allowable column load: Pa = (16.5)(4.43)/1.67 = 43.8 kips

Apply column load: P = {[(20)+(20)](30)(30)+(9)(15)}/1000 = 36.1 kip  O.K.

 

 

Disclaimer:  The content of this website was obtained and edited from various resources.  The editor made reasonable effort of editing.  Nevertheless, the editor does not warrant, and assume no liability for accuracy and completeness of its content.  The viewer shall use his/her professional knowledge and judgment in use of the web content.        Webmaster: www.ce-ref.com