CE-Ref.COM
|
|
| Design of W, I, S, HSS steel columns for axial compression (13 edition)Design code: AISC 13ed. Design requirementsLRFD (Load and Resistance Factor) design: LRFD design:
Where Pu is factored axial compressive force calculated based on strength design provision of building code. Pn is axial compressive strength calculated based on AISC 13th edition, f = 0.9 is resistance factor. ASD (Allowable Stress ) design:
Where Pa is axial compressive force calculated based on allowable stress design provision of building code, Pn is normal compressive strength calculated based on AISC 13th edition, W = 1.67 is safety factor. Design procedure:LRFD
ASD design:
Determine factored axial force, Pu for strength design & P for allowable stress designLoad combination factor: shall be determined according to applicable building code. Use ASCE 7 when building code is not available. Determine axial compressive strength, Pn
KxLx/rx and KyLy/ry where Lx ,Ly are laterally unsupported lengths in X and Y direction, rx ,rx are radius of gyrations in X and Y direction Ky ,Ky are slenderness factors in X and Y direction and can be determined as
Example
1: Situation: A structural column is supporting roof Design Code: AISC ASD 13th edition Roof
live load: WL = 20 psf Roof
dead load: WD = 20 psf Unsupported
Length of column: Lux = 15 ft, Luy = 15 ft Top
and bottom of column is pinned Tributary
area 30 ft x 30 ft Material:
ASTM A36, yield strength, Fy = 50 ksi Requirements:
Select a W6 beam Solution: Try
W6x15, A = 4.43 in2, rx = 2.56 in, ry = 1.46 in Slenderness
factor, Kx = 1, Ky = 1 Slenderness
ratio, KxLux/rx = 70.3, KyLuy/ry
= 123.3 Elastic
modulus, E = 29000 ksi parameter, l = (4.71)Ö(29000/50) = 113.4 < 123.3 Fe = (3.14)2(29000)/(123.3)2 = 18.83 ksi Fcr
= (0.877)(18.83)= 16.5 ksi LRFD solution Compressive strength of column, fPn = 0.9(4.43)(16.5) = 65.8 kips O.K. Factored
column load: Pu = {[(1.2)(20)+(1.6)(20)](30)(30)+1.2(15)(15)}/1000 =
50.67 kip ASD solution Allowable column load: Pa = (16.5)(4.43)/1.67 = 43.8 kips Apply column load: P = {[(20)+(20)](30)(30)+(15)(15)}/1000 = 36.2 kip O.K. Example
2: Situation:
In example 1 assume that the column is supported laterally at mid-height of
column in minor axis, Requirement:
Select an economical column Solution: Try
W6x9, A = 2.68 in2, rx = 2.47 in, ry = 0.905
in. Lateral
unsupported length, Lux = 15 ft, Luy = 7.5 ft Slenderness
ratio, KxLux/rx = 72.8, KyLuy/ry
= 99.4 Slenderness parameter, l = (4.71)Ö(29000/50) = 113.4 > 99.4 Fe = (3.14)2(29000)/(99.4)2 = 28.94 ksi Fcr
= [(0.658)(50/28.94)](50) = 24.26 ksi LRFD solution Compressive strength of column, fPn = 0.85(2.68)(26) = 59.2 kips Factored
column load: Pu = {[(1.2)(20)+(1.6)(20)](30)(30)+1.2(9)(15)}/1000 =
50.56 kip ASD solution Allowable column load: Pa = (16.5)(4.43)/1.67 = 43.8 kips Apply column load: P = {[(20)+(20)](30)(30)+(9)(15)}/1000 = 36.1 kip O.K.
|
| Disclaimer: The content of this website was obtained and edited from various resources. The editor made reasonable effort of editing. Nevertheless, the editor does not warrant, and assume no liability for accuracy and completeness of its content. The viewer shall use his/her professional knowledge and judgment in use of the web content. Webmaster: www.ce-ref.com |