Design of load bearing RC wall with empirical methodLimitation:ACI 318-05 Section 14.51. solid rectangular cross section. 2. resultant of all factored loads is located with the middle third of the overall thickness of the wall 3. Minimum thickness of wall shall not be less than 1/25 the support height of length or 4 inches. 4. Minimum thickness of exterior basement walls and foundation walls shall not be less than 7.5 inches. RC wall strength by empirical design method:The empirical equation for calculate axial strength of RC wall is fPn = 0.55 f fc' Ag [ 1 - ( k lc / 32 h)2] ACI 318 Eq (14.1) Where f = 0.65, lc is height of wall, h is thickness of wall, Ag is gross section area, fc' is compression strength of concrete, k is effective length factor. The effective length factor, k shall be For wall braced top and bottom against lateral translation, and 1. restrained against rotation at one or both ends, k = 0.8. 2. unrestrained against rotation at both ends, k = 1.0 For walls not braced against lateral translation, k = 2.0 Example 1:Design code: ACI 318-05 Section 14.5 Situation: A RC exterior wall supporting a two story building. Design data: Width of wall: h = 8 in Height of wall: lc = 12 ft. Compression strength of concrete: fc' = 3000 psi Yield strength of concrete: fy = 60000 psi Tributary width: 15 ft Roof live load: RL = 20 psf Roof dead load: RD = 80 psf Floor live load: FL = 100 psf Floor dead load: FD = 80 psf Lateral wind pressure: pw = 15 psf Lateral seismic force: pE = 10 psf Assumption: wall is continuous and restrained against rotation at top and bottom. Requirement: Design wall reinforcement using empirical design method Solution: Design for 1 ft width of wall: b = 1 ft Axial dead load: PD = FD *Trib*2*b + RD * Trib. b = 3.6 kips Axial roof live load: PRL = RL * Trib*b = 0.3 kips Axial floor live load: PFL = FL*Trib*b = 1.5 kip Axial wind load: PW = 0 Axial seismic load: PE = 0 Out-of-plan bending dead load moment: MD = 0 Out-of-plan bending Roof ive load moment:: MRL = 0 Out-of-plan bending floor live load moment: MFL = 0 From the continuous beam formula, the maximum negative moment is 0.1time span length lc. Out-of-plan bending wind load moment: MW = 0.1 * pw*lc2*b = 216 lb-ft Out-of-plan bending seismic load moment: ME = 0.1 * pE*lc2*b = 144 lb-ft Load combination: Case 1: Pu1 = 1.4 PD = 5.04 kip, Mu1 = 0 Eccentricity: eu1 = 0 Case 2: Pu2 = 1.2 PD + 1.6 PFL + 0.5 PRL = 6.87 kip Mu2 = 1.2 MD + 1.6 MFL + 0.5 MRL = 0 Eccentricity: eu2 = 0 Case 3: Pu3 = 1.2 PD + 1.6 PW + 1.0 PFL + 0.5 PRL = 5.97 kip Mu3 = 1.2 MD + 1.6 MW + + 1.0 MFL + 0.5 MRL = 0.346 ft-kip Eccentricity: eu3 = Mu3/Pu3 = 0.695 in < 8 in /6 = 1.33 in (O.K.) Case 4: Pu4 = 1.2 PD + 1.0 PE + 1.0 PFL = 5.82 kip Mu4 = 1.2 MD + 1.0 ME + + 1.0 MFL = 0.144 ft-kip Eccentricity: eu4 = Mu4/Pu4 = 0.297 in < 8 in /6 = 1.33 in (O.K.) Case 5: Pu5 = 0.9 PD + 1.6 PW = 3.24 kip Mu5 = 0.9 MD + 1.6 MW = 0.346 ft-kip Eccentricity: eu4 = Mu4/Pu4 = 1.28 in < 8 in /6 = 1.33 in (O.K.) Strength reduction factor: f = 0.65 Gross section: Ag = b* h = 96 in2 Effective length factor: k = 0.8 Design axial strength of wall: fPn = 0.55 f fc' Ag [ 1 - ( k lc / 32 h)2] = 82.1 kips Maximum axial load: Pu3 = 5.97 kips O.K. Check vertical reinforcement for bending moment, Maximum moment per foot width: Mu = 0.346 ft kip Use one layer of reinforcement, place at middle of the section: Effective depth: d = 4 in Factor: Rn = Mu / (0.9*b*d2) = 24 psi, m = fy / (0.85 fc' ) = 23.5 Reinforcement ratio: r = (1/m)*[1-Ö(1-2 m Rn / fy )] = 0.0004 Less than minimum vertical reinforcement ratio, use r = 0.0012 Vertical reinforcement: As = 0.0012 Ag = 0.115 in2. Use #4 at 18 in o.c. area of reinforcement, 0.133 in2. Minimum horizontal reinforcement: rt = 0.002, area of reinforcement, As = 0.192 in2. Use #4 at 12" o.c. area of reinforcement, 0.2 in2. |
| Disclaimer: The content of this website was obtained and edited from various resources. The editor made reasonable effort of editing. Nevertheless, the editor does not warrant, and assume no liability for accuracy and completeness of its content. The viewer shall use his/her professional knowledge and judgment in use of the web content. Webmaster: www.ce-ref.com |